INSTALLATION DATA
Installation Indoor or Outdoor
Environment Industrial, Marine
Amb. Temperature Min/Max -25°C (CS) and -40°C (LTCS) , storage only / 60°C *
OPERATING CONDITIONS
Fluids Fuels (HFO, LFO,MGO,DO,LSMGO); Mineral and synthetic lubricating oil;
Solid content 0% *
Viscosity range between 1.2 and 5000 cSt *
Speed between 750 and 3600 rpm *
Rotation (shaft view) Clockwise
Counter clockwise on request
TECHNICAL CHARACTERISTICS
Design available SEIM STANDARD
Flow rate between 0 and 41 lpm (between 0 and 2.46 m3/h; between 0 and 10.9 GPM) *
Suction pressure between -0.5 and 10 barg (between -8 and 146 psi) *
Delivery pressure 40 barg (581 psi) MAX *
Operating temperature between 0 and 150 °C *
Bearing DN40, ANSI 150
Drive AC or DC motor
IN/OUT connections DN32, PN40
MATERIALS
Body/Flange GGG40 *
O-rings standard Viton ®
Painting standard SA2,5 + primer + final, total 160µ approximately; other painting cycles on request
(*) For different values contact SEIM