INSTALLATION DATA | |
---|---|
Installation | Indoor or Outdoor |
Environment | Industrial, Marine |
Amb. Temperature Min/Max | -25°C (CS) and -40°C (LTCS) , storage only / 60°C * |
OPERATING CONDITIONS | |
Fluids | Fuels (HFO, LFO,MGO,DO,LSMGO); Mineral and synthetic lubricating oil; |
Solid content | 0% * |
Viscosity range | between 1.2 and 5000 cSt * |
Speed | between 750 and 3600 rpm * |
Rotation (shaft view) | Clockwise Counter clockwise on request |
TECHNICAL CHARACTERISTICS | |
Design available | SEIM STANDARD |
Flow rate | between 0 and 200 lpm (between 0 and 12 m3/h; between 0 and 52.9 GPM) * |
Suction pressure | between -0.5 and 10 barg (between -8 and 146 psi) * |
Delivery pressure | 16 barg (233 psi) MAX * | *
Operating temperature | between 0 and 150 °C * |
Drive | AC or DC motor * |
IN/OUT connections | DN40, ANSI 150 |
MATERIALS | |
Body/Flange | GGG40 * | O-rings | standard Viton ® | >
Painting | On request |
(*) For different values contact SEIM |